甲醛检测管NO. 91P,GASTEC甲醛检测管NO. 91P气体检测管,甲醛HCHO检测管NO. 91P,GASTEC甲醛检测管NO. 91P电泵用气体检测管检测范围0.02-1.44ppm。
产品描述
甲醛检测管NO. 91P
甲醛检测管
NO. 91PGASTEC甲醛检测管NO. 91P气体检测管,甲醛HCHO检测管NO. 91P,GASTEC甲醛检测管NO. 91P电泵用气体检测管检测范围0.02-1.44ppm。
GASTEC为了满足用户在气体检测方面的需要,而开发出了电子自动采气泵。用传统的电子吸气泵几乎不能进行有效的采气,因为检测管里的填充试剂密度很高。而GASTEC开发的GSP电泵系列能提供强劲吸力,能满足特定的检测管的取样要求。电泵和检测管组成的新的检测系统能适用于作业环境的检测。

Formaldehyde

NO.91P
HCHO 
甲醛检测管NO. 91P
Specifications
Calibration Range0.02-0.4 ppm
Measuring range0.02-1.44 ppm
Sampling (flow) Rate200mL/min
Sampling Volume6000mL, 2000mL
Sampling Time30min, 10min.
Detecting Limit0.01 ppm
Colour ChangeYellow → pink
Corrections for temperature/humidityTemperature
Shelf life1 year (in the refrigerator)
AccuracyCV=5-10%
(CV: Coefficient of variation = σ: standard deviation / mean value x 100)
Possibly coexisting substances and their interferences
Substance(s)InterferenceColour change by itself
Ammonia2 ppm (or less)NoNo
Nitrogen dioxide1 ppm (or less)NoNo
Acetaldehyde "+" error
(higher reading)
produces pinkish discolouration
Acetone0.3 ppm (or less)NoProduces pinkish stain around tube opening (inlet)
Ethanol NoNo
Ethyl acetate NoNo
p-dichlorobenzene NoNo
Toluene NoNo

Scrubber 1 (black): removes acetone

Scrubber 2 (purple):
Ammonia and nitrogen dioxide are removed. The presence of ammonia causes the purple scrubber 2 to turn yellow.

The presence of nitrogen dioxide causes scrubber 2 to turn a darker shade of purple
Calibration gas generationDiffusion tube method (analysis: by absorptiometry, acetylacetone method)
Miscellaneous
Electric sampling pump
This detector tube is suited for measuring formaldehyde in indoor environments. The GSP-200 / GSP-300FT series automatic gas samplers (or comparable sampling devices/pumps) should always be used for optimal performance.
A deviation of +/-10% in the sampling flowrate (i.e. amount of air flowing through the tube at a given moment) or the sampling amount (total sampled amount of target substance) causes an average margin of error of approx. +/-10% (maximum +/-20%) in the indicated value.
Formaldehyde indoor concentration threshold: 0.08 ppm (mean value during 30 minutes)
TLV-TWATLV-STELExplosive range
-- -- C0.3ppm7.0×73%
产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报
产品留言
标题
内容
联系人
联系电话
电子邮件
公司名称
联系地址
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!