产品规格
|
|
输出额定值
|
|
独立
|
0 V to 32 V, 0 A to 3 A (GPE-1323)
|
|
0 V to 20 V, 0 A to 5 A (GPE-1205)
|
|
串联(需要2台并搭配串联功能)
|
0 V to 64 V, 0 A to 3 A (GPE-1323)
|
|
0 V to 40 V, 0 A to 5 A (GPE-1205)
|
|
并联(需要2台并搭配并联功能)
|
0 V to 32 V, 0 A to 6 A (GPE-1323)
|
|
0 V to 20 V, 0 A to 10 A (GPE-1205)
|
|
定电压操作
|
|
电压调节率
|
≤ 0.01 % + 3 mV
|
|
负载调节率
|
≤ 0.01 % + 3 mV
|
|
≤ 0.01 % + 5 mV (≥ 3 A)
|
|
涟波 & 噪声
|
≤ 0.5 mVrms (5 Hz to 1 MHz)
|
|
设定范围
|
0 V to 33.6 V (GPE-1323)
|
|
0 V to 21 V (GPE-1205)
|
|
设定/回读准确率
|
± (0.03 % of reading + 10 mV)
|
|
分辨率
|
1 mV
|
|
*大感测补偿电压
|
1 V
|
|
反应时间
|
≤ 100 µs (50 % load change, minimum load 0.5 A)
|
|
温度系数
|
≤ 300 ppm/°C
|
|
定电流操作
|
|
电流调节率
|
≤ 0.2 % + 3 mA
|
|
负载调节率
|
≤ 0.2 % + 3 mA
|
|
涟波 & 噪声
|
≤ 2 mArms
|
|
设定范围
|
0 A to 3.15 A (GPE-1323)
|
|
0 A to 5.25 A (GPE-1205)
|
|
设定/回读准确率
|
0.1 mA
|
|
分辨率
|
± (0.3 % of reading + 10 mA)
|
|
温度系数
|
≤ 300 ppm/°C
|
|
PROTECTION
|
|
过电压保护 OVP
|
范围
|
OFF, ON (1.8 V to 35.2 V) (GPE-1323)
|
|
OFF, ON (1.0 V to 22.0 V) (GPE-1205)
|
|
分辨率
|
100 mV
|
|
准确率
|
≤ ± 100 mV
|
|
过电流保护 OCP
|
范围
|
OFF, ON (0.15 A to 3.3 A) (GPE-1323)
|
|
OFF, ON (0.25 A to 5.5 A) (GPE-1205)
|
|
分辨率
|
10 mA
|
|
准确率
|
≤ ± 20 mA
|
|
显示
|
|
显示器
|
2.4-inch TFT LCD
|
|
设定/回读分辨率
|
电压:100 µV
|
|
电流:10 µA
|
|
设定/回读分辨率
|
电压:± (0.03 % of reading + 10 mV)
|
|
电流:± (0.3 % of reading + 10 mA)
|
|
绝缘
|
|
|
Chassis and Terminal
|
20 MΩ or above (DC 500 V)
|
|
Chassis and AC cord
|
30 MΩ or above (DC 500 V)
|
|
环境
|
|
操作环境
|
室内使用,海拔高度≤2000米
|
|
环境温度:0℃~40℃
|
|
相对湿度:≤80%
|
|
安装类别:Ⅱ类;污染等级:2
|
|
储存环境
|
环境温度:-10 ℃~70 ℃
|
|
相对湿度:≤ 70%
|
|
电源及功耗
|
|
电源
|
AC (100 V, 120 V, 220 V, 240 V) ± 10 %, 50 or 60 Hz
|
|
电源功耗
|
300 VA
|
|
尺寸及重量
|
|
尺寸
|
107 mm x 124 mm x 313 mm, (W x H x D)
|
|
重量
|
约 5.2 公斤
|
|
附件
|
|
标配
|
电源线 x 1, 包装清单 x 1,
|
|
测试线: 台规 GTL-104A x 1
|
|
测试线: 欧规 GTL-204A x 1
|
|
选购
|
GTL-234 RS-232C 缆线, 9 针 (母对母)
|
|
GRA-441-J 仪器架套件 JIS
|
|
GRA-441-E 仪器架套件 EIA
|