R2600便携式无线电综合测试仪频率范围:400HZ-999.9999MHZ 功能:射频信号源;频率计数器;场强计;灵敏测量接收机;AC/DC电压表;信纳比表;频谱分析仪;射频功率计;畸变分析仪;双工偏移发生器;扫描发生器;示波器;信令编码/***。
产品描述

特性介绍:

Operating / Display:
Modes

AM/FM Monitor
AM/FM Generate
Audio Synthesizer
Spectrum Analyzer
Duplex Generator
Sweep Generator
Frequency Counter
Digital Voltmeter
Wattmeter
Oscilloscope
Signal Strength Meter
SINAD/Distortion Meter

 RF Signal Generator:
FREQUENCY  
Range: 400 kHz - 1 GHz
Resolution: 100 Hz
Accuracy: Refer to Accuracy of Master Oscillator
Stabilization Time: .1 Second
   
OUTPUT  
Range FM: -130 dBm to 0 dBm
Range AM: -130 dBm to -3 dBm
Accuracy: ±2 dB from -0.80 dBm to -130 dBm (RF I/O PORT)
  ±4 dBm for all other output levels and ports. 3 MHz to 1 GHz
   
SWEEP GENERATOR
Range; 400 kHz - 1 GHz
Resolution: 100 Hz
Output: -130 dBm to 0 dBm
Sweep Width: Selectable up to ±5 MHz of center freq.
Scope Coupling: Synchronized scope trace to the sweep signal
Accuracy: Same as Signal Generator
   
DUPLEX GENERATOR
Range: 400 kHz - 1 GHz
Resolution: 100 Hz
Output: -130 dBm to 0 dBm
Frequency Offset: 0 MHz to ±55 MHz in 5 kHz steps
Accuracy: Same as Signal Generator
   
SPECTRA PURITY
Spurious: 35 dB within ±20 MHz of selected carrier frequency. Additional fixed spurs at an absolute level of <90 dBm at harmonic frequencies of 5 MHz. (These can affect level and modulation measurements when operated at low levels at or very near these specific frequencies.)
Harmonics: - 20 dBc
   
FM MODULATION
Deviation: 99.5 kHz
Accuracy: 5% of setting ±25 Hz @ 1 kHz (NB)
5% of setting ±250 Hz @ 1 kHz (WB)
Residual FM: 20 Hz max @ 300 Hz to 3 kHz
External/Internal Frequency Range: 5 Hz to 20 kHz, ±2 dB
   
PHASE MODULATION (Optional)
Range: 0.5 to 10 radians
Accuracy: ±8% at 1 KHz
Resolution: 1 radians (.01 below 2.00 radians) External/Internal
Internal/External Frequency Range: 300 to 3000 Hz
 Audio Modulation Synthesizer:
   
Modulation Types: 1 kHz tone, PRIVATE LINE, DIGITAL PRIVATE LINE, Single Tone, DTMF, Two-Tone Paging, 5/6 Tone Paging, International Select V, 20 Tone General Sequence, Tone Remote Control, External inputs from both a supplied microphone and BNC input.
Frequency Range: 10 Hz to 20 kHz ±1 dB
Mod Output Level: Programmable into 7.95 v peak
Mod Input Impedance: 100 ohms nominal
1 kHz Tone Distortion: Not to exceed 1%
External Modulation Input: Front panel microphone and a BNC jack are summed
BNC Input Impedance: 600 ohms nominal
Microphone Supplied: HMN1056
Microphone Input Conditioning: Internal audio limiting providing IDC and pre-emphasis.
 RF Receiver:
   
FREQUENCY  
Range: 400 kHz - 1 GHz
Resolution: 100 Hz
Accuracy: Refer to Accuracy of Master Oscillator
Spurious Response: 40 dB typical
   
SENSITIVITY (Above 10 MHz)
Narrowband FM: 2.0 uV for 10 dB EIA SINAD
Wideband FM: 10 uV for 10 dB EIA SINAD
   
FREQUENCY ERROR METER
Type of Display: ; Autoranging
Resolution: 1 Hz
   
FM DEVIATION MEASUREMENT
Demod Range: Up to ±5 kHz in Narrowband
Up to ±75 kHz in Wideband
Accuracy: ±5% plus peak residual FM
Frequency Response: Selectable per the following:
Low Pass Filters 20 kHz, 3kHz, 300Hz
High Pass Filters 5 Hz, 300 Hz, 3kHz
Demodulated Output Level: .8 v peak per 1 kHz peak Deviation in Narrowband and per 10 kHz Deviation in Wideband
Demodulation Output Impedance: 100 ohms nominal
Deviation Alarm: Audible, set via keypad in 100 Hz increments
   
AM MODULATION MEASUREMENTS
Demodulation Range: 0 to 100%
Accuracy: ±5% for levels below 80%
Frequency Response: Selectable per the following:
Low Pass Filters 20 kHz, 3 kHz, 300 Hz
High Pass Filters 5 Hz, 300 Hz, 3 kHz
Demodulated Output Level: .8v peak per 10% AM modulation
   
PHASE MODULATION (Optional)
Demod Range: Narrowband = 1 radian
Wideband = 10 radians
Accuracy/Frequency Response: ±5% ±0.1 rad, ± residual noise at 1 kHz,
±7.5% ±0.1 rad, ± residual noise 300 Hz to 3.5 kHz
 Metering and Measurement
SPECTRUM ANALYZER - SEE AND HEAR™
Frequency Range: 400 kHz to GHz
Dispersion: Selectable from keypad per following:
200 kHz window - (20 kHz per div)
500 kHz window - (50 kHz per div)
1 MHz window - (100 kHz per div)
2 MHz window - (200 kHz per div)
5 MHz window - (500 kHz per div)
10 MHz window - (1 MHz per div)
Optional: 20 MHz window - (2 MHz per div)*
50 MHz window - (5 MHz per div)*
100 MHz window - (10 MHz per div)*
* SEE AND HEARª not functional
Dynamic Range 60dB
Bandwidth: Automatically selected:
6 kHz - (100 kHz per division & below)
30 kHz - (200 kHz per division & below)
Display Range: +50 to -95 dBm
Optional Markers: Freeze, Max Hold, Peak Hold Delta or Absolute level and frequency
   
SIGNAL STRENGTH INDICATOR
Range: 3 MHz to 1 GHz
Accuracy: ±4 dB
Sensitivity: -100 dBm (antenna port rating)
   
WATTMETER (RF I/O PORT)
Frequency Range: 3 MHz to 1 GHz
Measurement Range: .1 watt to 125 watts
Input Impedance: Input Impedance: 50 ohms with maximum VSWR of 1.5:1
Accuracy: ±10%
Protection: Over temperature alarms
   
TRACKING GENERATOR
Frequency Range: 400 kHz to 1 GHz
Tracking Display Sweep Range: 200 kHz window - (20 kHz per div)
500 kHz window - (50 kHz per div)
1 MHz window - (100 kHz per div)
2 MHz window - (200 kHz per div)
5 MHz window - (500 kHz per div)
10 MHz window - (1 MHz per div)
20 MHz window - (2 MHz per div)
50 MHz window - (5 MHz per div)
Display Range: 0 to -80 dBm
   
CABLE FAULT (Optional)
Method: Standing Wave Analysis
Measure: Fault distance, cable length
Reading: Feet and meters
Accuracy: 10%
   
OSCILLOSCOPE
CRT Size: 9 cm x 11 cm (approx. 7 inch diagonal) raster scan display with four intensity levels
Frequency Response: 0 to 50 kHz
Vertical Input Ranges: Selectable per the following:
10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1v, 2v, 5v, 10v per division
Accuracy: 5% of full scale all ranges
Sweep Ranges: Selectable per the following:
20 usec, 50 usec, 100 usec, 200 usec, 500 usec, 1 msec, 2 msec, 5 msec, 10 msec, 20 msec, 50 msec, 100 msec, 200 msec, 500 msec, 1 sec per division
Trigger: Automatic, normal and single sweep
Optional Markers: Delta Voltage, Delta Frequency, Delta Period
   
DIGITAL VOLTMETER
Meter Type: RMS
Frequency Range: DC plus AC of 50 Hz to 20 kHz
DC Voltage Ranges: 1.0V, 10.0 V, 100 V full scale
Accuracy: 1% full scale ±1 least significant digit
   
AC Voltage Ranges: 1.0V, 10.0 V, 70 V full scale
Accuracy: 5% full scale ±1 least significant digit
   
Freq. Response: 3 dB end points @ 50 Hz and 20 kHz
   
FREQUENCY COUNTER
Frequency Range: 5 Hz to 500 kHz plus Auto Tune
Period Counter Range: 5 Hz to 20 kHz
Input Level:: .1 v RMS minimum input level
Resolution: .1 Hz, 1 Hz, 10 Hz, 100 Hz and 1 kHz varying by frequency range
Auto Tune: Monitor mode, 20 MHz to 1 GHz unit will scan and find signals greater than -30 dBm
Accuracy: See TIME BASE
   
SINAD / DISTORTION METER
Input Level: .1 V to 10 V RMS
SINAD Accuracy: ±1 dB at 12 dB SINAD
Distortion Range: 1% to 20%
Distortion Accuracy: ±0.5% of distortion of ±10% of reading whichever is greater
Optional: C-Message Filter; CCITT Filter w/600 ohm switchable load
   
TONE SEQUENCE DECODE
Modulation Types: PRIVATE LINE, DIGITAL PRIVATE LINE, Single Tone, DTMF, Two-Tone Paging, 5/6 Tone Paging, International Select V, 20 Tone General Sequence.
Frequency Accuracy: ±3% from 300 Hz to 3 kHz
Duration Accuracy: ±12 msec for tones greater than 30 msec and 300 Hz
   
RS232 PORT (Requires special cable)/Optional IEEE-488 Bi-directional port provided with capability to respond to serial (optional parallel) input command vocabulary to activate functions and return measured results. Baud rates to 9600 BPS with selectable start and parity bits.
   
TIME BASE  
Standard TCXO: Aging 1 ppm/yr, Temperature 1 ppm
Optional OCXO: Aging .5 ppm/yr, Temperature .05 ppm
 Power and Environmental:
AC: 100-130 VRMS or 200-260 VRMS@ 50 Hz to 440 Hz
DC: +11 to +16 VDC
Battery Option: 13.6 V, 50 minutes typical
Dimensions: 8.5Óhigh x 16Ó wide x 17Ó deep (21.6 cm x 40.7 cm x 43.2 cm) excluding accessories, battery pack and cover
Weight: 33 pounds (Basic model excluding accessory cover)
Temperature:

0 C to +50 C (operating)
-40 C to +85 C (storage)

 Interface Ports:
Printer / Remote Control: RS-232 DB25 (female)
Color Monitor: Standard CGA, RGB, DB9 (female)

 

简单操作说明如下:

§2.2 控制键和控制钮
§2.2.1 键/钮及指示SS ,
电源开关——按开关ON,所有电路即通上电。如果有外接交流电,仪器自动用交流电;否则,仪器转
为使用直流电。在按下ON时,仪器就完成自动选择。
ON指示灯——按下ON时此灯亮。
DC指示灯—一当仪器使用直流电时,此灯亮。
游标区按键(RF,AUD及DISP)——确定游标在CRT三个显示区中在哪个区有效。换区后,游标停
留在上次在该区所在的位置。
游标位置键(Up,Down,Left,Right,TAB)——此5键用于将游标上(Up)、下(Down)、左(Left)、右
(Right)或跳某位(TAB)地移动。
帮助(HELP)键——按下可显示用于当前屏幕的帮助信息。
内存(MEM)键——可用于内存内容的预置。
数字键(o—9)——用于向测试仪输入数字信息。按某数字键,则游标所在处的数字被此键代表的数代
替。仪器按新输入的数工作。如果所按的数字超出允许值,则该输入被忽略,原先显示的数字不变。
+/—键——将所显示的某一值的符号反向。
ALT键——按此键使某一键的另一种替代功能起作用,此时,屏幕上的信息行显示ALT,再按任何
其他键后,屏幕上的ALT消失。
SPF键——显示特别功能菜单。
PRT键——把屏幕上显示的内容打印出来。
CAL键—一命令仪器进行自校准。
P1键一—保留用作用户选择的特别功能。现用此键来从遥控工作方式转为本地工作方式。

软按键——在屏幕的下部。软按键的功能随游标所在位置的变化而变化,从而对现行游标位置提供一
个菜单以指示所有可能值或输入,
§2.2.2 旋钮
: sQuELcH(静噪)——静噪控制。顺时针旋转会增加静噪打开时的信号电平门限值。
vOLUME(音量)——控制喇叭的音量。
BRIGHT(亮度)硕顺时针旋转可增加亮度.

§2.2.3 CRT显示屏
这是点阵化了的9cmXllcm阴极射线管显示,显示内容包括数据、操作控制和指导性信息.显示方式包括数字、模拟及条状图。

cRT在*后一次操作后的大约30分钟内会进入一种亮度减弱的节省状态。
§2.2.4 插头座
RF IN/OUT___通过皮端口把射频输入信号接到机内的监视器,或输出机内产生的信号,在双工工作方式时,经由此端口提供组合的输入、出信号。皮端口包含射频率计的负载。在前面板上,这是**可以输入大功率射频的端口。
GEN OUT——-此口与监视输入口相互独立,由它提供高电平的射频输出。请勿由此口输入大功率射频!
ANT—灵敏监视接收机的输入端口,对测量空中电波很有用处。切勿由此口输入大功率射频!
注 意
在GEN OUT和ANT的插座中装有射频保险丝以防过载,用一个板手把BNC型插府的前端部分拧下来,就可以更换保险丝。保险丝的零件号为GG-6530277C002。保险丝应剪成0.48正负0.02英寸(12.2正负0.05mm)长,其两端应修尖以适合安装。
VERT/SINAD DIST/DVM COUNTER IN——此端口用作示波器Y轴、信纳比表、DVM(数字万用表)/计数器、畸变计、DVM以及频率计数器的输入端。
DEMOD OUT——恢复)(解调)后的音频输出端口(在监视或双工工作方式下)。
EXT MOD IN——外部调制信号输入端口。为**显示电平,要求输入信号为固定的峰一峰值1伏信号。
MIC——外接话筒端口。
2.2.4.2侧面板插座
RGB PORT(九针)——用于外接CGA格式的彩色监视器。
RS-232 PORT(25针)——用于外接打印机或其它控制器。
2.2.4.3后面板插座
10MHz STD——BNC型插座,由此端口接入或接出10MHz参考频率。输入阻抗为50欧。对输入电平的要**70mV到1Vrms,输出电平大约为250uVrms.

The R-2600 Communications System Analyzer is a portable test instrument designed to monitor and service radio communications equipment over the frequency range of 400 Hz to 999.9999 MHz. The analyzer generates signals, measures modulation and frequency and performs a variety of tests normally associated with a whole host of other devices including signal generators, oscilloscopes volmeters and distortion analyzers. This unit employs a large CRT display which simultaneously presents control and data displays. A simplified front panel with soft keys, cursor keys and more all combine to make the unit extremely easy to learn and very efficient to use. Here are some of the Modes: Monitor, Generate, Duplex, Sweep generate, Audio/Modulation Synthesizer, DTMG Audio Monitor, Meter

产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
  • 温馨提示:为规避购买风险,建议您在购买前务必确认供应商资质与产品质量。
  • 免责申明:以上内容为注册会员自行发布,若信息的真实性、合法性存在争议,平台将会监督协助处理,欢迎举报
产品留言
标题
内容
联系人
联系电话
电子邮件
公司名称
联系地址
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!